 | Input Signal: 0.08 to 50 pulses per
foot (0.26 to 164 pulses per meter) from any MSDI sender or sender adapter.
|
 | Speed Range: 0 - 99.9 MPH (0 - 99.9
km/hr).
|
 | Speed Resolution: 0.1 MPH (0.1 km/hr).
|
 | Response Speed: 1.4 sec. maximum.
|
 | Odometer Range: 0 to 9999 Miles (km),
resettable to zero.
|
 | Power Supply: 11-14 Volts DC, 0.5
amp, negative ground.
|
 | Limits: Adjustable high and low speed
limits, 0.1 to 99.9 MPH (0.1 to 99.9 km/hr). Visual and operator selectable
audible warning. Auto limit shut-off for speeds under 1/2 of the lower limit and
over 10 MPH (10 km/hr) above the upper limit.
|
 | Power Off Memory: Stores limits, current odometer
reading and calibration data. Does not require power to maintain memory.
|
 | Temperature: 32° to 131° F, (0°-55° C.) Accuracy is
unaffected by temperature.
|
 | Mounting: Due to the wide variety of mounting
requirements for the S40B, it is supplied with hand knobs but no yoke.
|
 | The S40B is supplied with a 15 foot cable. Longer
cables available for small additional cost.
|
 | The S40B requires a sender, and may share a sender with
a skipline control on the same vehicle. See
Accessories
for available sender
options.
|
 | Certain electronic automatic transmissions (such as Allison
MD3060) are directly compatible with the S40B and no additional sender or
adapter is
required. |